Product Feature:
FG series rigid rod explosion-proof liquid level sensor, using the side and straight line, explosion-proof form has the flame-proof and this two kinds of Ann, is widely applied in place for flammable and explosive environment.
—
—Explosion-proof marks ExdIIBT5/ExiaIIBT5
—High degree of protection(IP68)
—
—
— Can provide double interface level measurement (oil/gas, oil/water)
Technical Parameters:
Analog Output | SSI Output | |
---|---|---|
Project Name | Standard/Parameter | Standard/Parameter |
Measurement Range | 50-5000mm | 50-5000mm |
Output Signal | 4~20mADC; 0~10VDC | RTU Signal , RS485 |
Resolution | 16 bit D/A | 0.1mm |
Non-linearity | <±0.05%F.S. | <±0.05%F.S. |
Hysteresis | <±0.002%F.S. | <±0.002%F.S. |
The temperature coefficient of | 0.007%F.S./℃ | |
Operating Voltage | 24VDC (-15/+20%) | |
Working Temp | - 40℃~+85℃ | |
Protective Ability | Ordinary type, flameproof, the Ann model | |
Way To Install | Installed thread, flange (optional) |
Boundary Dimension |
---|
|
Electrical Connection:
Analog Output | Needle Size | Line Color | Definition | Modbus Output | Needle Size | Line Color | Definition |
---|---|---|---|---|---|---|---|
1 | grey | Output Signal:4-20mA,0-10V | 1 | grey | A(RS485) | ||
2 | pink | Signal earth | 2 | pink | B(RS485) | ||
3 | palm | +24VDC(±10%) | 3 | palm | +24VDC(±10%) | ||
4 | white | A direct current source | 4 | white | A direct current source |