FB series - integral flange

2015-01-20 1327

Product Feature:

  FB series liquid level sensor adopts flange design, electronic sensor head flange has realized the integration of parts and installation, compact structure, exposed part after installation height only 34 mm.

      — Strong anti-interference ability

      — High degree of protection(IP68)

      — Easy installation and use

      — High precision

 

Technical Parameters:

  Analog Output SSI Output
Project Name Standard/Parameter Standard/Parameter
Measurement Range 50-5000mm 50-5000mm
Output Signal 4~20mADC; 0~10VDC Modbus RS485
Resolution 16 bit D/A  0.1mm
Non-linearity <±0.05%F.S. <±0.05%F.S.
Hysteresis <±0.002%F.S. <±0.002%F.S.
The temperature coefficient of 0.007%F.S./℃
Operating Voltage 24VDC (-15/+20%)
Working Temp - 40℃~+85℃
Protective Ability Ordinary type, flameproof, the Ann model
Way To Install Installed thread, flange (optional)

 

Overall dimensions:

 

Electrical connections:

 

Analog Output Needle Size Line Color Definition Modbus输出 Needle Size Line Color Definition
1 grey Output Signal:4-20mA,0-10V 1 grey A(RS485)
2 pink Signal earth 2 pink B(RS485)
3 yellow throw out of gear 3 yellow throw out of gear
4 green throw out of gear 4 green throw out of gear
5 palm +24VDC(±10%) 5 palm +24VDC(±10%)
6 white A direct current source 6 white A direct current source

 

Analog Output Needle Size Line Color Definition Modbus Output Needle Size Line Color Definition
1 grey Output Signal:4-20mA,0-10V 1 grey A(RS485)
2 pink Signal earth 2 pink B(RS485)
3 palm +24VDC(±10%) 3 palm +24VDC(±10%)
4 white A direct current source 4 white A direct current source